Description
It is essential to match the reset type and temperature rating of the original equipment to maintain the UL safety certification of the furnace
It is intended for a single motor circuit (either compressor or fan) and does not include a secondary "common" or "fan" terminal found on dual-type units
Interchangeable Design: The 068U103000 allows for rapid capacity adjustments in the field without breaking brazed joints
Direct Mount Interface: Simplifies installation by eliminating the need for additional capillary tubes or mounting brackets
It is compatible with any Building Automation System (BAS) or controller calibrated for a 1k ohm nickel RTD (Nickel-Iron Balco) input curve
Copeland 940-0140-08 Potential Relay Els PW 17895 It is essential to matchThe Copeland 940 0140 08 Potential Relay is a critical OEM compressor start component designed to manage the start up cycle of high torque single phase motors. Operating at a nominal 290 VAC rating, this relay leverages the back EMF generated by the motor's start winding to precisely time the removal of the start capacitor from the circuit. With a calibrated pick up voltage range of 340 360 VAC and a drop out voltage of 50 100 VAC, it ensures the